Component - Plastics | E344082 | |
CELANESE INTERNATIONAL CORP | ||
ZENITE BUSINESS LINE, 8040 DIXIE HWY, FLORENCE KY 41042-2904 | ||
6130L(m) | ||
Liquid Crystal Polymer (LCP) "ZENITE", furnished as pellets |
Color | Min. Thk (mm) | Flame Class | HWI | HAI | RTI Elec | RTI Imp | RTI Str |
BK, WT | 0.25 | V-0 | 3 | 4 | 130 | 130 | 130 |
BK | 0.38 | V-0 | 3 | 4 | 240 | 130 | 130 |
0.75 | V-0 | 3 | 4 | 240 | 220 | 240 | |
WT | 1.0 | V-0 | 3 | 4 | 240 | 220 | 240 |
ALL | 1.5 | V-0 | 1 | 4 | 240 | 220 | 240 |
3.0 | V-0 | 0 | 4 | 240 | 220 | 240 |
Comparative Tracking Index (CTI): | 3 | Inclined Plane Tracking (IPT) kV: | - |
Dielectric Strength (kV/mm): | 21 | Volume Resistivity (10x ohm-cm): | - |
High-Voltage Arc Tracking Rate (HVTR): | 4 | Surface Resistivity (10x ohms/square): | - |
Dimensional Change (%): | - | High Volt, Low Current Arc Resis (D495): | - |
RoHS 2011/65/EU & 2015/863 Compliant Material (color: BK) | |||
UL 746H Non-Halogenated Material (color: BK) |
(m) - | Virgin and regrind up to 50% have the same basic characteristics down to the 0.38 mm thickness except for the Electrical RTI rating below the 0.75 mm thickness. |
NOTE - | (1) Material designations that are color pigmented may be followed by suffix letters and numbers. (2) Material designations may be prefixed by "ZEN" for Zenite grades. |
ANSI/UL 94 small-scale test data does not pertain to building materials, furnishings and related contents. ANSI/UL 94 small-scale test data is intended solely for determining the flammability of plastic materials used in the components and parts of end-product devices and appliances, where the acceptability of the combination is determined by UL. |
Report Date: | 1989-10-11 | © 2022 UL Solutions | |
Last Revised: | 2022-11-30 |
IEC and ISO Test Methods | ||||
Test Name | Test Method | Units | Thk (mm) | Value |
Flammability | IEC 60695-11-10 | Class (color) | 0.25 | V-0 (BK, WT) |
0.38 | V-0 (BK) | |||
0.75 | V-0 (BK) | |||
1.0 | V-0 (WT) | |||
1.5 | V-0 (ALL) | |||
3.0 | V-0 (ALL) | |||
Glow-Wire Flammability (GWFI) | IEC 60695-2-12 | °C | 0.75 | 960 |
1.0 | 960 | |||
1.5 | 960 | |||
3.0 | 960 | |||
Glow-Wire Ignition (GWIT) | IEC 60695-2-13 | °C | 0.75 | 850 |
1.0 | 825 | |||
1.5 | 825 | |||
3.0 | 875 | |||
IEC Comparative Tracking Index | IEC 60112 | Volts (Max) | - | - |
IEC Ball Pressure | IEC 60695-10-2 | °C | - | - |
ISO Heat Deflection (1.80 MPa) | ISO 75-2 | °C | - | - |
ISO Tensile Strength | ISO 527-2 | MPa | - | - |
ISO Flexural Strength | ISO 178 | MPa | - | - |
ISO Tensile Impact | ISO 8256 | kJ/m2 | - | - |
ISO Izod Impact | ISO 180 | kJ/m2 | - | - |
ISO Charpy Impact | ISO 179-1 | kJ/m2 | - | - |