Component - Plastics | E41871 | |
BASF SE | ||
Performance Materials Europe, PMD/EX - H201, Ludwigshafen 67056 DE | ||
A3X2G10(f2), A3X3G10(f2), A3X2G10 LF(f2), A3X2G10 BMB(f2) | ||
Polyamide 66 (PA66) "Ultramid", furnished as pellets |
Color | Min. Thk (mm) | Flame Class | HWI | HAI | RTI Elec (°C) | RTI Imp (°C) | RTI Str (°C) |
NC, BK | 0.40 | V-2 | 4 | 1 | 65 | 65 | 65 |
0.60 | V-2 | 1 | 1 | 105 | 105 | 120 | |
NC, BK, GY | 0.75 | V-2 | 1 | 1 | 110 | 115 | 130 |
NC, GY | 1.5 | V-0 | 0 | 1 | 115 | 115 | 130 |
3.0 | V-0 | 0 | 1 | 115 | 115 | 130 | |
BK | 1.5 | V-0, 5VA | 0 | 1 | 115 | 115 | 130 |
3.0 | V-0, 5VA | 0 | 1 | 115 | 115 | 130 |
Comparative Tracking Index (CTI): | 0 | Inclined Plane Tracking (IPT) kV: | - |
Dielectric Strength (kV/mm): | 21 | Volume Resistivity (10x ohm-cm): | 13 |
High-Voltage Arc Tracking Rate (HVTR): | 0 | Surface Resistivity (10x ohms/square): | - |
Dimensional Change (%): | 0 | High Volt, Low Current Arc Resis (D495): | 5 |
(f2) - | Subjected to one or more of the following tests: Ultraviolet Light, Water Exposure or Immersion in accordance with UL 746C, where the acceptability for outdoor use is to be determined by UL. |
ANSI/ UL 94 small-scale test data does not pertain to building materials, furnishings and related contents. ANSI/UL 94 small-scale test data is intended solely for determining the flammability of plastic materials used in the components and parts of end-product devices and appliances, where the acceptability of the combination is determined by UL. |
Report Date: | 1974-10-24 | © 2025 UL Solutions | ![]() |
Last Revised: | 2024-12-23 |
IEC and ISO Test Methods | ||||
Test Name | Test Method | Units | Thk (mm) | Value |
Flammability | IEC 60695-11-10, IEC 60695-11-20 | Class (color) | 0.40 | V-2 (NC, BK) |
0.60 | V-2 (NC, BK) | |||
0.75 | V-2 (NC, BK, GY) | |||
1.5 | V-0 (NC, GY) | |||
3.0 | V-0 (NC, GY) | |||
1.5 | V-0, 5VA (BK) | |||
3.0 | V-0, 5VA (BK) | |||
Glow-Wire Flammability (GWFI) | IEC 60695-2-12 | °C | - | - |
Glow-Wire Ignition (GWIT) | IEC 60695-2-13 | °C | - | - |
IEC Comparative Tracking Index | IEC 60112 | Volts (Max) | - | - |
IEC AC Dielectric Strength (AC DS) | IEC 60243-1 | kV/mm | - | - |
IEC DC Dielectric Strength (DC DS) | IEC 60243-2 | kV/mm | - | - |
IEC Volume Resistivity (VR) | IEC 62631-3-1 | 10x ohm-m | - | - |
IEC Surface Resistivity (SR) | IEC 62631-3-2 | 10x ohms | - | - |
IEC Inclined Plane Tracking (IPT) | IEC 60587 | kV | - | - |
IEC Ball Pressure | IEC 60695-10-2 | °C | - | - |
ISO Heat Deflection (1.80 MPa) | ISO 75-2 | °C | - | - |
ISO Tensile Strength | ISO 527-2 | MPa | - | - |
ISO Flexural Strength | ISO 178 | MPa | - | - |
ISO Tensile Impact | ISO 8256 | kJ/m2 | - | - |
ISO Izod Impact | ISO 180 | kJ/m2 | - | - |