Component - Plastics | E41797 | |
TORAY INDUSTRIES INC | ||
NIHONBASHI-MITSUI TOWER, 1-1 NIHONBASHI-MUROMACHI 2-CHOME, CHUO-KU TOKYO 103-8666 JP | ||
A504X90, A504X95, A504FG1, A504, A504CX1, A504CX2 (R) | ||
Polyphenylene Sulfide (PPS) "Torelina", furnished as pellets |
Color | Min. Thk (mm) | Flame Class | HWI | HAI | RTI Elec | RTI Imp | RTI Str |
ALL | 0.28 | V-0 | - | - | 130 | 130 | 130 |
0.71 | V-0 | 1 | 1 | 200 | 200 | 200 | |
1.5 | V-0 | 0 | 1 | 220 | 200 | 210 | |
3.0 | V-0 | 0 | 0 | 220 | 200 | 210 |
Comparative Tracking Index (CTI): | 4 | Inclined Plane Tracking (IPT) kV: | - |
Dielectric Strength (kV/mm): | 21 | Volume Resistivity (10x ohm-cm): | 16 |
High-Voltage Arc Tracking Rate (HVTR): | 1 | Surface Resistivity (10x ohms/square): | - |
Dimensional Change (%): | 0.0 | High Volt, Low Current Arc Resis (D495): | 5 |
(R) - | Virgin and regrind up to 50% by weight inclusive have the same V-0 flammability and tensile impact characteristics when used within the 130 C generic temperature limitation: no other properties for regrind 26-50% by wt. incl. have been determined. |
NOTE - | Polyamide (nylon) grades may be prefixed with the letters CM and may employ hyphens in various locations. The designations of ECODEAR products may employ hyphens and/or spaces in various locations. All grades that include ABS, SAN, and/or PC (designations of TOYOLAC or TOYOLACPAREL or TORAYCA products) may employ hyphens and/or spaces and may be suffixed with 3 or 4 digits of letters and/or numbers. |
ANSI/UL 94 small-scale test data does not pertain to building materials, furnishings and related contents. ANSI/UL 94 small-scale test data is intended solely for determining the flammability of plastic materials used in the components and parts of end-product devices and appliances, where the acceptability of the combination is determined by UL. |
Report Date: | 1994-07-14 | © 2022 UL Solutions | ![]() |
Last Revised: | 2022-11-07 |
IEC and ISO Test Methods | ||||
Test Name | Test Method | Units | Thk (mm) | Value |
Flammability | IEC 60695-11-10 | Class (color) | 0.28 | V-0 (ALL) |
0.71 | V-0 (ALL) | |||
1.5 | V-0 (ALL) | |||
3.0 | V-0 (ALL) | |||
Glow-Wire Flammability (GWFI) | IEC 60695-2-12 | °C | - | - |
Glow-Wire Ignition (GWIT) | IEC 60695-2-13 | °C | - | - |
IEC Comparative Tracking Index | IEC 60112 | Volts (Max) | - | - |
IEC Ball Pressure | IEC 60695-10-2 | °C | - | - |
ISO Heat Deflection (1.80 MPa) | ISO 75-2 | °C | - | - |
ISO Tensile Strength | ISO 527-2 | MPa | - | - |
ISO Flexural Strength | ISO 178 | MPa | - | - |
ISO Tensile Impact | ISO 8256 | kJ/m2 | - | - |
ISO Izod Impact | ISO 180 | kJ/m2 | - | - |
ISO Charpy Impact | ISO 179-1 | kJ/m2 | - | - |