Component - Plastics | E41938 | |
CELANESE INTERNATIONAL CORP | ||
8040 DIXIE HWY, FLORENCE KY 41042-2904 | ||
FR530(l)(+)(f1), FR530L(l)(+)(f1) | ||
Polyethylene Terephthalate (PET), glass reinforced, flame retardant "Rynite", furnished as pellets [contains mechanically recycled content] |
Color | Min. Thk (mm) | Flame Class | HWI | HAI | RTI Elec (°C) | RTI Imp (°C) | RTI Str (°C) |
NC, BK | 0.35 | V-0 | 3 | 1 | 155 | 155 | 155 |
ALL | 0.75 | V-0 | 2 | 1 | 155 | 155 | 155 |
NC, BK | 1.5 | V-0, 5VA | 0 | 1 | 155 | 155 | 155 |
ALL | 2.0 | V-0, 5VA | 0 | 1 | 155 | 155 | 155 |
3.0 | V-0, 5VA | 0 | 1 | 155 | 155 | 155 |
Comparative Tracking Index (CTI): | 2 | Inclined Plane Tracking (IPT) kV: | - |
Dielectric Strength (kV/mm): | 34 | Volume Resistivity (10x ohm-cm): | 16 |
High-Voltage Arc Tracking Rate (HVTR): | 1 | Surface Resistivity (10x ohms/square): | - |
Dimensional Change (%): | 0 | High Volt, Low Current Arc Resis (D495): | 6 |
(+) - | Virgin and regrind up to 50% by weight inclusive, have the same basic material characteristics. |
(f1) - | Suitable for outdoor use with respect to exposure to Ultraviolet Light, Water Exposure and Immersion in accordance with UL 746C. |
(l) - | Recognized ground insulation component at 0.4 mm with MW79 in UL1446 Class 155 electrical insulation system designated R201N (File E69939). |
NOTE - | (1) Material designations that are color pigmented may be followed by suffix letters and numbers. (2) Material designations may be prefixed by "ZYT" for Zytel or "MIN" for Minlon or "DEL" for Delrin or "CRA" for Crastin or "RYN" for Rynite or "ETPV" for ETPV or "SOR" for Sorona grades. |
ANSI/UL 94 small-scale test data does not pertain to building materials, furnishings and related contents. ANSI/UL 94 small-scale test data is intended solely for determining the flammability of plastic materials used in the components and parts of end-product devices and appliances, where the acceptability of the combination is determined by UL. |
Report Date: | 1996-01-04 | © 2023 UL Solutions | ![]() |
Last Revised: | 2023-02-17 |
IEC and ISO Test Methods | ||||
Test Name | Test Method | Units | Thk (mm) | Value |
Flammability | IEC 60695-11-10, IEC 60695-11-20 | Class (color) | 0.35 | V-0 (NC, BK) |
0.75 | V-0 (ALL) | |||
1.5 | V-0, 5VA (NC, BK) | |||
2.0 | V-0, 5VA (ALL) | |||
3.0 | V-0, 5VA (ALL) | |||
Glow-Wire Flammability (GWFI) | IEC 60695-2-12 | °C | 0.75 | 960 |
1.5 | 960 | |||
2.0 | 960 | |||
3.0 | 960 | |||
Glow-Wire Ignition (GWIT) | IEC 60695-2-13 | °C | 0.75 | 800 |
1.5 | 800 | |||
2.0 | 985 | |||
3.0 | 985 | |||
IEC Comparative Tracking Index | IEC 60112 | Volts (Max) | - | - |
IEC Ball Pressure | IEC 60695-10-2 | °C | - | 245 |
ISO Heat Deflection (1.80 MPa) | ISO 75-2 | °C | - | - |
ISO Tensile Strength | ISO 527-2 | MPa | - | - |
ISO Flexural Strength | ISO 178 | MPa | - | - |
ISO Tensile Impact | ISO 8256 | kJ/m2 | - | - |
ISO Izod Impact | ISO 180 | kJ/m2 | - | - |
ISO Charpy Impact | ISO 179-1 | kJ/m2 | - | - |