Component - PlasticsE41938
CELANESE INTERNATIONAL CORP
8040 DIXIE HWY, FLORENCE KY 41042-2904
FR530(l)(+)(f1), FR530L(l)(+)(f1)
Polyethylene Terephthalate (PET), glass reinforced, flame retardant "Rynite", furnished as pellets [contains mechanically recycled content]

Color
Min. Thk
(mm)
Flame
Class

HWI

HAI
RTI Elec
(°C)
RTI Imp
(°C)
RTI Str
(°C)
NC, BK0.35V-031155155155
ALL0.75V-021155155155
NC, BK1.5V-0, 5VA01155155155
ALL2.0V-0, 5VA01155155155
3.0V-0, 5VA01155155155
Comparative Tracking Index (CTI):2Inclined Plane Tracking (IPT) kV:-
Dielectric Strength (kV/mm):34Volume Resistivity (10x ohm-cm):16
High-Voltage Arc Tracking Rate (HVTR):1Surface Resistivity (10x ohms/square):-
Dimensional Change (%):0High Volt, Low Current Arc Resis (D495):6
(+) - Virgin and regrind up to 50% by weight inclusive, have the same basic material characteristics.
(f1) - Suitable for outdoor use with respect to exposure to Ultraviolet Light, Water Exposure and Immersion in accordance with UL 746C.
(l) - Recognized ground insulation component at 0.4 mm with MW79 in UL1446 Class 155 electrical insulation system designated R201N (File E69939).
NOTE - (1) Material designations that are color pigmented may be followed by suffix letters and numbers. (2) Material designations may be prefixed by "ZYT" for Zytel or "MIN" for Minlon or "DEL" for Delrin or "CRA" for Crastin or "RYN" for Rynite or "ETPV" for ETPV or "SOR" for Sorona grades.
ANSI/UL 94 small-scale test data does not pertain to building materials, furnishings and related contents. ANSI/UL 94 small-scale test data is intended solely for determining the flammability of plastic materials used in the components and parts of end-product devices and appliances, where the acceptability of the combination is determined by UL.
Report Date:1996-01-04© 2023 UL Solutions
Last Revised:2023-02-17
 
IEC and ISO Test Methods
Test NameTest MethodUnitsThk (mm)Value
FlammabilityIEC 60695-11-10, IEC 60695-11-20Class (color)0.35V-0 (NC, BK)
0.75V-0 (ALL)
1.5V-0, 5VA (NC, BK)
2.0V-0, 5VA (ALL)
3.0V-0, 5VA (ALL)
Glow-Wire Flammability (GWFI)IEC 60695-2-12°C0.75960
1.5960
2.0960
3.0960
Glow-Wire Ignition (GWIT)IEC 60695-2-13°C0.75800
1.5800
2.0985
3.0985
IEC Comparative Tracking IndexIEC 60112Volts (Max)--
IEC Ball PressureIEC 60695-10-2°C-245
ISO Heat Deflection (1.80 MPa)ISO 75-2°C--
ISO Tensile StrengthISO 527-2MPa--
ISO Flexural StrengthISO 178MPa--
ISO Tensile ImpactISO 8256kJ/m2--
ISO Izod ImpactISO 180kJ/m2--
ISO Charpy ImpactISO 179-1kJ/m2--

back