Component - Plastics | E45329 | |
SABIC INNOVATIVE PLASTICS B V | ||
EUROPE - RESIN, PLASTICSLAAN 1, BERGEN OP ZOOM Noord-Brabant 4612 PX NL | ||
101(f2), 101R(f2), 121(f2), 121R(f2), 141(f2), 141R(f2) | ||
Polycarbonate (PC) "Lexan", furnished as pellets |
Color | Min. Thk (mm) | Flame Class | HWI | HAI | RTI Elec (°C) | RTI Imp (°C) | RTI Str (°C) |
ALL | 0.7 | HB | - | - | 115 | 115 | 115 |
1.1 | HB | 3 | 2 | 115 | 115 | 115 | |
1.5 | HB | 3 | 0 | 130 | 125 | 125 | |
3.0 | HB | 2 | 1 | 130 | 130 | 130 |
Comparative Tracking Index (CTI): | 2 | Inclined Plane Tracking (IPT) kV: | - |
Dielectric Strength (kV/mm): | 25 | Volume Resistivity (10x ohm-cm): | 15 |
High-Voltage Arc Tracking Rate (HVTR): | 2 | Surface Resistivity (10x ohms/square): | - |
Dimensional Change (%): | 0 | High Volt, Low Current Arc Resis (D495): | 6 |
(f2) - | Subjected to one or more of the following tests: Ultraviolet Light, Water Exposure or Immersion in accordance with UL 746C, where the acceptability for outdoor use is to be determined by UL. |
NOTE - | Material designation may be followed by a color nomenclature consisting of either an alpha/numeric or a numeric/alpha combination. |
ANSI/UL 94 small-scale test data does not pertain to building materials, furnishings and related contents. ANSI/UL 94 small-scale test data is intended solely for determining the flammability of plastic materials used in the components and parts of end-product devices and appliances, where the acceptability of the combination is determined by UL. |
Report Date: | 1977-11-21 | © 2023 UL Solutions | |
Last Revised: | 2023-02-23 |
IEC and ISO Test Methods | ||||
Test Name | Test Method | Units | Thk (mm) | Value |
Flammability | IEC 60695-11-10 | Class (color) | 0.7 | HB, HB75 (ALL) |
1.1 | HB, HB75 (ALL) | |||
1.5 | HB, HB75 (ALL) | |||
3.0 | HB, HB40 (ALL) | |||
Glow-Wire Flammability (GWFI) | IEC 60695-2-12 | °C | - | - |
Glow-Wire Ignition (GWIT) | IEC 60695-2-13 | °C | - | - |
IEC Comparative Tracking Index | IEC 60112 | Volts (Max) | - | - |
IEC Ball Pressure | IEC 60695-10-2 | °C | - | - |
ISO Heat Deflection (1.80 MPa) | ISO 75-2 | °C | - | - |
ISO Tensile Strength | ISO 527-2 | MPa | - | - |
ISO Flexural Strength | ISO 178 | MPa | - | - |
ISO Tensile Impact | ISO 8256 | kJ/m2 | - | - |
ISO Izod Impact | ISO 180 | kJ/m2 | - | - |
ISO Charpy Impact | ISO 179-1 | kJ/m2 | - | - |