| Component - Plastics | E41871 | |
| BASF SE | ||
| Performance Materials Europe, PMD/EX - H201, Ludwigshafen 67056 DE | ||
| A3X2G5(f2)(r), A3X2G5 BMB (f2)(r) | ||
| Polyamide 66 (PA66), glass reinforced "Ultramid", furnished as pellets | ||
Color | Min. Thk (mm) | Flame Class | HWI | HAI | RTI Elec (°C) | RTI Imp (°C) | RTI Str (°C) |
| NC, BK | 0.40 | HB | 4 | 0 | 110 | 115 | - |
| 0.60 | HB | 2 | 0 | 110 | 115 | - | |
| NC, BK, GY | 0.81 | V-0 | 0 | 0 | 120 | 115 | 130 |
| 1.5 | V-0 | 0 | 0 | 120 | 115 | 130 | |
| 3.0 | V-0, 5VA | 0 | 0 | 120 | 115 | 130 |
| Comparative Tracking Index (CTI): | 0 | Inclined Plane Tracking (IPT) kV: | 1 |
| Dielectric Strength (kV/mm): | 19 | Volume Resistivity (10x ohm-cm): | 11 |
| High-Voltage Arc Tracking Rate (HVTR): | 1 | Surface Resistivity (10x ohms/square): | - |
| Dimensional Change (%): | 0 | High Volt, Low Current Arc Resis (D495): | 6 |
| (f2) - | Subjected to one or more of the following tests: Ultraviolet Light, Water Exposure or Immersion in accordance with UL 746C, where the acceptability for outdoor use is to be determined by UL. |
| (r) - | Virgin and regrind up to 50% by weight inclusive have the same flammability characteristics for black (BK) colored material only, excluding UL 746C suitability for outdoor use coverage (f2) and Incline Plane Tracking |
| colspan="2">ANSI/ UL 94 small-scale test data does not pertain to building materials, furnishings and related contents. ANSI/UL 94 small-scale test data is intended solely for determining the flammability of plastic materials used in the components and parts of end-product devices and appliances, where the acceptability of the combination is determined by UL. |
| Report Date: | 1974-10-24 | © 2025 UL Solutions | ![]() |
| Last Revised: | 2024-12-30 |
| IEC and ISO Test Methods | ||||
| Test Name | Test Method | Units | Thk (mm) | Value |
| Flammability | IEC 60695-11-10, IEC 60695-11-20 | Class (color) | 0.40 | HB, HB75 (NC, BK) |
| 0.60 | HB, HB75 (NC, BK) | |||
| 0.81 | V-0 (NC, BK, GY) | |||
| 1.5 | V-0 (NC, BK, GY) | |||
| 3.0 | V-0, 5VA (NC, BK, GY) | |||
| Glow-Wire Flammability (GWFI) | IEC 60695-2-12 | °C | - | - |
| Glow-Wire Ignition (GWIT) | IEC 60695-2-13 | °C | - | - |
| IEC Comparative Tracking Index | IEC 60112 | Volts (Max) | - | - |
| IEC AC Dielectric Strength (AC DS) | IEC 60243-1 | kV/mm | - | - |
| IEC DC Dielectric Strength (DC DS) | IEC 60243-2 | kV/mm | - | - |
| IEC Volume Resistivity (VR) | IEC 62631-3-1 | 10x ohm-m | - | - |
| IEC Surface Resistivity (SR) | IEC 62631-3-2 | 10x ohms | - | - |
| IEC Inclined Plane Tracking (IPT) | IEC 60587 | kV | - | - |
| IEC Ball Pressure | IEC 60695-10-2 | °C | - | 252 |
| ISO Heat Deflection (1.80 MPa) | ISO 75-2 | °C | - | - |
| ISO Tensile Strength | ISO 527-2 | MPa | - | - |
| ISO Flexural Strength | ISO 178 | MPa | - | - |
| ISO Tensile Impact | ISO 8256 | kJ/m2 | - | - |
| ISO Izod Impact | ISO 180 | kJ/m2 | - | - |
| ISO Charpy Impact | ISO 179-1 | kJ/m2 | - | - |