Component - Plastics | E245249 | |
LANXESS AG | ||
Chempark Dormagen, Bu Hpm, Building F46, Dormagen Nordrhein-Westfalen 41538 DE | ||
AKV30H2.0+, ECOAKV30H2.0+, AKV30H2.0+LT, AKV30H3.0+, AKV30H3.0LT+ | ||
Polyamide 66 (PA66), glass reinforced "DURETHAN", furnished as pellets |
Color | Min. Thk (mm) | Flame Class | HWI | HAI | RTI Elec (°C) | RTI Imp (°C) | RTI Str (°C) |
ALL | 0.75 | HB | 4 | 0 | 125 | 90 | 110 |
1.5 | HB | 4 | 0 | 125 | 105 | 115 | |
3.0 | HB | 3 | 0 | 125 | 105 | 115 | |
6.0 | HB | 1 | 0 | 125 | 105 | 115 |
Comparative Tracking Index (CTI): | 1 | Inclined Plane Tracking (IPT) kV: | - |
Dielectric Strength (kV/mm): | 25 | Volume Resistivity (10x ohm-cm): | 11 |
High-Voltage Arc Tracking Rate (HVTR): | 1 | Surface Resistivity (10x ohms/square): | - |
Dimensional Change (%): | 0.0 | High Volt, Low Current Arc Resis (D495): | 6 |
+ - | Material designations may be followed by suffix numbers and/or letter(s) denoting color. |
ANSI/UL 94 small-scale test data does not pertain to building materials, furnishings and related contents. ANSI/UL 94 small-scale test data is intended solely for determining the flammability of plastic materials used in the components and parts of end-product devices and appliances, where the acceptability of the combination is determined by UL. |
Report Date: | 1979-04-13 | © 2023 UL Solutions | ![]() |
Last Revised: | 2023-03-15 |
IEC and ISO Test Methods | ||||
Test Name | Test Method | Units | Thk (mm) | Value |
Flammability | IEC 60695-11-10 | Class (color) | 0.75 | HB, HB75 (ALL) |
1.5 | HB, HB75 (ALL) | |||
3.0 | HB, HB40 (ALL) | |||
6.0 | HB, HB40 (ALL) | |||
Glow-Wire Flammability (GWFI) | IEC 60695-2-12 | °C | 0.75 | 700 |
1.5 | 700 | |||
3.0 | 700 | |||
6.0 | 700 | |||
Glow-Wire Ignition (GWIT) | IEC 60695-2-13 | °C | 0.75 | 725 |
1.5 | 725 | |||
3.0 | 750 | |||
6.0 | 750 | |||
IEC Comparative Tracking Index | IEC 60112 | Volts (Max) | - | - |
IEC Ball Pressure | IEC 60695-10-2 | °C | - | 258 |
ISO Heat Deflection (1.80 MPa) | ISO 75-2 | °C | - | - |
ISO Tensile Strength | ISO 527-2 | MPa | - | - |
ISO Flexural Strength | ISO 178 | MPa | - | - |
ISO Tensile Impact | ISO 8256 | kJ/m2 | - | - |
ISO Izod Impact | ISO 180 | kJ/m2 | - | - |
ISO Charpy Impact | ISO 179-1 | kJ/m2 | - | - |