Component - Plastics | E116324 | |
RADICINOVACIPS SPA | ||
VIA BEDESCHI 20, CHIGNOLO D'ISOLA BG 24040 IT | ||
Radiflam A RV250 AF(k)(f1) | ||
Polyamide 66 (PA66), furnished as granular material |
Color | Min. Thk (mm) | Flame Class | HWI | HAI | RTI Elec (°C) | RTI Imp (°C) | RTI Str (°C) |
NC, BK | 0.75 | V-0 | 1 | 0 | 115 | 100 | 130 |
1.5 | V-0, 5VA | 1 | 0 | 115 | 100 | 130 | |
3.0 | V-0, 5VA | 1 | 0 | 115 | 100 | 130 |
Comparative Tracking Index (CTI): | 1 | Inclined Plane Tracking (IPT) kV: | - |
Dielectric Strength (kV/mm): | 5 | Volume Resistivity (10x ohm-cm): | - |
High-Voltage Arc Tracking Rate (HVTR): | 1 | Surface Resistivity (10x ohms/square): | - |
Dimensional Change (%): | - | High Volt, Low Current Arc Resis (D495): | 6 |
(f1) - | Suitable for outdoor use with respect to exposure to Ultraviolet Light, Water Exposure and Immersion in accordance with UL 746C. |
(k) - | Alphanumeric code consisting of 3 to 4 digits or letters starting with "3" for black color or starting with "8" for natural color. Natural may appear to be brown. |
ANSI/UL 94 small-scale test data does not pertain to building materials, furnishings and related contents. ANSI/UL 94 small-scale test data is intended solely for determining the flammability of plastic materials used in the components and parts of end-product devices and appliances, where the acceptability of the combination is determined by UL. |
Report Date: | 1990-03-28 | © 2023 UL Solutions | ![]() |
Last Revised: | 2023-02-10 |
IEC and ISO Test Methods | ||||
Test Name | Test Method | Units | Thk (mm) | Value |
Flammability | IEC 60695-11-10, IEC 60695-11-20 | Class (color) | 0.75 | V-0 (NC, BK) |
1.5 | V-0, 5VA (NC, BK) | |||
3.0 | V-0, 5VA (NC, BK) | |||
Glow-Wire Flammability (GWFI) | IEC 60695-2-12 | °C | 0.75 | 960 |
1.5 | 960 | |||
3.0 | 960 | |||
Glow-Wire Ignition (GWIT) | IEC 60695-2-13 | °C | 0.75 | 700 |
1.5 | 675 | |||
3.0 | 800 | |||
IEC Comparative Tracking Index | IEC 60112 | Volts (Max) | - | - |
IEC Ball Pressure | IEC 60695-10-2 | °C | - | - |
ISO Heat Deflection (1.80 MPa) | ISO 75-2 | °C | - | - |
ISO Tensile Strength | ISO 527-2 | MPa | - | - |
ISO Flexural Strength | ISO 178 | MPa | - | - |
ISO Tensile Impact | ISO 8256 | kJ/m2 | - | - |
ISO Izod Impact | ISO 180 | kJ/m2 | - | - |
ISO Charpy Impact | ISO 179-1 | kJ/m2 | - | - |