Component - Plastics | E47960 | |
DSM ENGINEERING PLASTICS B V | ||
POSTBUS 604, GELEEN 6160 AP NL | ||
TE250F6(h1)(j) | ||
Polyamide 46 (PA46), glass reinforced, flame retardant, "Stanyl", furnished as pellets |
Min Thk | Flame | RTI | RTI | RTI | |||
Color | (mm) | Class | HWI | HAI | Elec | Imp | Str |
ALL | 0.35 | V-0 | 0 | 0 | - | - | - |
0.75 | V-0 | 0 | 0 | 140 | 110 | 120 | |
1.5 | V-0 | 0 | 0 | 140 | 125 | 125 | |
3.0 | V-0 | 0 | 0 | 140 | 130 | 130 |
Comparative Tracking Index (CTI): | 2 | Inclined Plane Tracking (IPT): | - |
Dielectric Strength (kV/mm): | 23 | Volume Resistivity (10x ohm-cm) : | - |
High-Voltage Arc Tracking Rate (HVTR): | 1 | High Volt, Low Current Arc Resis (D495): | 6 |
Dimensional Stability (%): | 0.0 |
(h1) - | Virgin and regrind, up to 50% by weight inclusive, in thicknesses of 0.75mm and greater, have the same basic material characteristics, except for CTI. |
(j) - | Virgin and regrind, up to 100% by weight inclusive, have the same basic material characteristics with respect to Flammability in the 0.75mm thickness and greater. |
ANSI/UL 94 small-scale test data does not pertain to building materials, furnishings and related contents. ANSI/UL 94 small-scale test data is intended solely for determining the flammability of plastic materials used in the components and parts of end-product devices and appliances, where the acceptability of the combination is determined by UL. |
Report Date:
2003-01-01 Last Revised: 2013-05-29 |
© 2013 UL LLC |
![]() |
IEC and ISO Test Methods |
Thickness | ||||
Test Name | Test Method | Units | Tested (mm) | Value |
Flammability | IEC 60695-11-10 | Class (color) | 0.35 | V-0 (ALL) |
0.75 | V-0 (ALL) | |||
1.5 | V-0 (ALL) | |||
3.0 | V-0 (ALL) | |||
Glow-Wire Flammability (GWFI) | IEC 60695-2-12 | C | - | - |
Glow-Wire Ignition (GWIT) | IEC 60695-2-13 | C | - | - |
IEC Comparative Tracking Index | IEC 60112 | Volts (Max) | - | - |
IEC Ball Pressure | IEC 60695-10-2 | C | 3.0 | 285 |
ISO Heat Deflection (1.80 MPa) | ISO 75-2 | C | - | - |
ISO Tensile Strength | ISO 527-2 | MPa | - | - |
ISO Flexural Strength | ISO 178 | MPa | - | - |
ISO Tensile Impact | ISO 8256 | kJ/m2 | - | - |
ISO Izod Impact | ISO 180 | kJ/m2 | - | - |
ISO Charpy Impact | ISO 179-2 | kJ/m2 | - | - |
© 2013 UL LLC |