| Component - Plastics | E47960 |
| Envalior | |
| Flughafenstrasse 101, Dusseldorf, 40474 Germany | |
| TE250F6(h1)(j) | |
| Polyamide 46 (PA46) "Stanyl", glass reinforced, flame retardant, furnished as pellets |
|
Color
|
Min. Thk
(mm)
|
Flame
Class
|
HWI
(PLC)
|
HAI
(PLC)
|
GWIT
(°C)
|
GWFI
(°C)
|
RTI Elec
(°C)
|
RTI Imp
(°C)
|
RTI Str
(°C)
|
|---|---|---|---|---|---|---|---|---|---|
| ALL | 0.35 | V-0 | 0 | 0 | -- | -- | -- | -- | -- |
| 0.75 | V-0 | 0 | 0 | -- | -- | 140 | 110 | 120 | |
| 1.5 | V-0 | 0 | 0 | -- | -- | 140 | 125 | 125 | |
| 3.0 | V-0 | 0 | 0 | -- | -- | 140 | 130 | 130 |
| Comparative Tracking Index (CTI) (PLC): | 2 | IEC Comparative Tracking Index (V): | -- | IEC CTI Material Group: | -- |
| Inclined Plane Tracking (IPT) (kV): | -- | High-Voltage Arc Tracking Rate (HVTR) (PLC): | 1 | Dielectric Strength (DS) (kV/mm): | 23 |
| Volume Resistivity (VR) (10x ohm cm): | -- | Surface Resistivity (SR) (10x ohms/square): | -- | High Volt, Low Current Arc Resis (D495): | 6 |
| (h1) - Virgin and regrind, up to 50% by weight inclusive, in thicknesses of 0.75mm and greater, have the same basic material characteristics, except for CTI. |
| ANSI/UL 94 small-scale test data does not pertain to building materials, furnishings and related contents. ANSI/UL 94 small-scale test data is intended solely for determining the flammability of plastic materials used in the components and parts of end-product devices and appliances, where the acceptability of the combination is determined by UL. |
| Report Date: 2003-01-01 |
| Last Revised: 2025-11-14 |
![]() |
| © 2026 UL Solutions |
| ISO/IEC Flammability Properties | Value | Test Method | |
| Flammability |
IEC 60695-11-10
|
||
|
0.35 mm, Color: ALL
|
V-0
|
|
|
|
0.75 mm, Color: ALL
|
V-0
|
|
|
|
1.5 mm, Color: ALL
|
V-0
|
|
|
|
3.0 mm, Color: ALL
|
V-0
|
|