Component - Plastics
|
E41871 |
|
BASF SE |
|
ENGINEERING PLASTICS EUROPE, E-KTE/MP - F206, LUDWIGSHAFEN 67056 DE |
|
A3X2G5(f2)(r) |
|
Polyamide 66 (PA66), glass reinforced, "Ultramid", furnished as pellets |
| | Min Thk | Flame | | | RTI | RTI | RTI |
| Color | (mm) | Class | HWI | HAI | Elec | Imp | Str |
| NC, BK | 0.40 | HB | 4 | 0 | 110 | 115 | - |
| 0.60 | HB | 2 | 0 | 110 | 115 | - |
| NC, BK, GY | 0.81 | V-0 | 0 | 0 | 120 | 115 | 130 |
| 3.0 | V-0, 5VA | 0 | 0 | 120 | 115 | 130 |
| 1.5 | V-0 | 0 | 0 | 120 | 115 | 130 |
| Comparative Tracking Index (CTI): | 0 | Inclined Plane Tracking (IPT): | 109 min at 1kV |
| Dielectric Strength (kV/mm): | 19 | Volume Resistivity (10x ohm-cm) : | 11 |
| High-Voltage Arc Tracking Rate (HVTR): | 1 | High Volt, Low Current Arc Resis (D495): | 6 |
| Dimensional Stability (%): | 0 | | |
| ANSI/UL
94 small-scale test data does not pertain to building materials,
furnishings and related contents. ANSI/UL 94 small-scale test data is
intended solely for determining the flammability of plastic materials
used in the components and parts of end-product devices and appliances,
where the acceptability of the combination is determined by UL. |
|
Report Date:
1974-10-24
Last Revised:
2012-01-19 |
© 2012 UL LLC |
 |
| | | Thickness | |
| Test Name | Test Method | Units | Tested (mm) | Value |
| Flammability | IEC 60695-11-10, IEC 60695-11-20 | Class (color) | 0.40 | HB75 (NC, BK) |
| | | 0.60 | HB75 (NC, BK) |
| | | 0.81 | V-0 (NC, BK, GY) |
| | | 3.0 | V-0, 5VA (NC, BK, GY) |
| | | 1.5 | V-0 (NC, BK, GY) |
| Glow-Wire Flammability (GWFI) | IEC 60695-2-12 | C | - | - |
| Glow-Wire Ignition (GWIT) | IEC 60695-2-13 | C | - | - |
| IEC Comparative Tracking Index | IEC 60112 | Volts (Max) | - | - |
| IEC Ball Pressure | IEC 60695-10-2 | C | - | - |
| ISO Heat Deflection (1.80 MPa) | ISO 75-2 | C | - | - |
| ISO Tensile Strength | ISO 527-2 | MPa | - | - |
| ISO Flexural Strength | ISO 178 | MPa | - | - |
| ISO Tensile Impact | ISO 8256 | kJ/m2 | - | - |
| ISO Izod Impact | ISO 180 | kJ/m2 | - | - |
| ISO Charpy Impact | ISO 179-2 | kJ/m2 | - | - |
|
|